16 HDV100A3 Command & Response Manual
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Set Filter Off
Byte
Number
Byte
Value
Function
1
01
Start of frame
2
02
Control bytes
3
01
ID byte 1 = J1708 message
4
X8
Set filter 8 = Set filter inactive X = filter number 1 to 4
6
00
Data bytes
7
CS
Checksum
Setting all filters off will stop all data from the J1708 bus. When all filters
are set off you must send the receive J1708 command to start receiving all
bus messages.